Find a tool

Drywall Calculators

Sheets hung run by run, plus joint compound, tape, screws and corner bead.

These pages hang board on a room and count the sheets, screws, compound, tape and bead, with screw spacing checked against IRC Table R702.3.5. They are an estimate for planning; a licensed trade signs off the work, and your local authority decides which edition applies and whether a garage needs a fire-rated ceiling.

An isometric room corner with one drywall sheet shaded

Which of these 9 pages is yours

Not sure which one? Start with the Drywall Calculator — it handles the general case, and the links under its answer carry your measurements to the next page.

Page The question it answers The number it prints largest
Drywall Your room, the openings out — the sheets and everything that goes with them. Prints: Buy
Joint compound The mud a room takes, in the pails a store sells. Prints: Joint compound
Drywall screws Counted off the code table, sheet by sheet. Prints: Screws
Drywall tape The tape a room takes, and which roll covers it. Prints: Joint tape
Ceiling drywall Just the ceiling — and the screws a ceiling really takes. Prints: Buy
Drywall cost Sheets, screws, mud and tape — what they come to. Prints: Ticked items cost
Garage drywall The board a garage takes, and what it weighs. Prints: Buy
4×8 or 4×12 The same room, every sheet size, side by side. Prints: Buy
Corner bead Count your outside corners; we do the sticks. Prints: Outside corner bead

How a room is measured for board

A room is five numbers: length, width, wall height, and how many doors and windows it has, boarded on the walls, the ceiling or both. A wall or a ceiling on its own is a rectangle, a gable end is a triangle, and an opening too big to hang over — a 16 by 7 foot garage door — is a part you subtract.

Doors and windows come out of the area, not out of the sheets. Board is hung across an opening and the hole cut after, so a door saves no sheets, but the compound and the tape are worked from the surface that is left. The 12 by 10 foot room with 8 foot walls that the pages open with is 472 square feet gross and 439 net, a 3 by 7 foot door and a 3 by 4 foot window out.

Sheets are hung, not divided

Board goes on in rows. An 8 foot wall takes two rows of 4 foot sheets, each as long as the wall, and the piece cut off one row starts the next. Laid out that way the 12 by 10 room hangs 15 sheets of 4 by 8 — 14 whole, and the ceiling's last 2 foot strip ripped from part of one more — and buys 17 with 10% for breakage. Dividing the area, with its 10%, by a 4 by 8 gives 16, and a division cannot say which size wastes least.

Every size is laid out the same way, and the page hangs the cheapest with the others beside it, each with its count, offcut and cost. Here 11 sheets of 4 by 12 cost $241.78 against $239.70 for the 4 by 8s. That $2.08 is well inside the error of prices we estimated, so type your store's first; the sizes page sets them side by side. The 54 inch width is laid out and priced too, and never picked for you: it is a pro-yard item, made for 9 foot walls.

A wall that is not a whole number of rows ends in a strip. A 9 foot wall is two rows of 4 foot board and a 12 inch strip, and the page rips strips four to a sheet, as a hanger does, rather than buying a whole sheet for every strip row. The garage page, 20 by 20 feet with 9 foot walls in 5/8 inch Type X, comes to 31 sheets of 4 by 10. Walls can be hung upright as well; a ceiling has no upright, so it is not asked.

Screws come off the code table

IRC Table R702.3.5 sets the spacing by plane and framing. Half-inch board on walls framed 16 inches on center takes a screw every 16 inches, and on a ceiling every 12, so a 4 by 8 sheet takes 28 screws on a wall and 35 on a ceiling. The 12 by 10 room takes 452, and on 4 by 12s, 430: the count follows the sheet you hang. Counting sheet by sheet counts a screw on a shared edge twice, which is the safe side for a shopping list, and the page says so.

Where the numbers come from

Table R702.3.5 was read in the text of IRC 2021 and IRC 2024; the clause keeps its number and every spacing in both. Board weights come from the mills' submittal and data sheets, screws to the pound from a screw maker's table, and tape from a joint tape data sheet. The compound, 9 gallons per 1,000 square feet, is one maker's rule of thumb in a FAQ rather than a coverage off a data sheet, and is labeled an estimate. The door and window sizes and the 10% waste are conventions; a small room with a ceiling lays out nearer 13%. Every price is an estimate, one per sheet size whatever the thickness.

The fastener check meets the table while the spacing boxes hold its figures, and fails if you type a wider one. The ceiling check is marked "Not checked" at 24 inches on center: there the table lists ceiling board one way only, across the joists, and the page cannot see which way you will hang it. The garage ceiling check never passes. Under a habitable room the table asks for 5/8 inch Type X with fasteners every 6 inches, and whether the room above is habitable is not a measurement.

What these pages do not do

They do not stagger the butt joints. The layout starts each row with the last one's offcut but does not care whether two rows end on the same stud; the sheet count is the same either way, and where the joints fall is not.

The strips are counted beside the cutting list, not drawn in it: the width of a sheet is the one dimension the list does not lay out. A gable end is counted by its area.

They do not offer adhesive, which lets the table space wall screws wider, because board fastened for glue that was never applied comes down. They do not offer 3/8 or 1/4 inch board, or a compound figure per finish level.

They do not decide whether a garage needs fire separation; the authority that inspects the job does. And they do not price labor, or count screws for steel framing.

What this cluster assumes

12 assumptions: 9 from a data sheet or an agency document, 2 trade convention, 1 derived or single-supplier

Every constant these pages show under Assumptions, on the project each one opens with and on every choice its form offers, with its tier and the document it was read from. Each one is editable on the page that uses it; the waste each page starts at is in its own box, beside the form.

Assumption Value Confidence
Compound per unit areaUSG's FAQ gives two 4.5 gal pails of UltraLightweight All Purpose compound per 1,000 ft² of board, which is 9 gal per 1,000 ft². It is one maker's rule of thumb for one product in a FAQ rather than a coverage off a data sheet, and a setting-type compound mixed from powder will differ. Inch Calculator works in lb/ft² and publishes no figure, so there is nothing of theirs to compare. ~ 0.009 gal/ft² Derived or single-supplier
One door openingA 3 x 7 ft opening; Benjamin Moore takes 21 ft² for a door too. The paint cluster takes 20 ft², the finished leaf, because paint stops at the casing and board is cut to the opening. Neither 20 nor 21 is a measured rough opening: both are conventions, and the box is there for anyone who has measured theirs. ≈ 21 ft² Trade convention
Board weight, 5/8 in Type XNominal weight of 5/8 in Type X board. USG Sheetrock Firecode X product page; Gold Bond Fire-Shield submittal 111098 (05/23). 2.2 lb/ft² From a data sheet or an agency document
Board weight, 1/2 in regularNominal weight of 1/2 in regular gypsum board. Gold Bond submittal 110638 (04/15); CertainTeed gives 1.6 as well. Inch Calculator works at about 1.7, which is 6-7% over what the mills publish. 1.6 lb/ft² From a data sheet or an agency document
Board weight, 1/2 in lightweightNominal weight of 1/2 in lightweight board. USG Sheetrock UltraLight data sheet WB2501 (4/2020). 1.25 lb/ft² From a data sheet or an agency document
Screw spacing, ceilingIRC Table R702.3.5, ceiling, without adhesive: screws not more than 12 in apart, at 16 and at 24 in framing alike. Same figure in the IRC 2021 and IRC 2024 text. 12 in From a data sheet or an agency document · source
Screw spacing, wall at 16 in o.c.IRC Table R702.3.5, wall, framing 16 in o.c., application without adhesive: screws not more than 16 in apart. Same figure in the IRC 2021 and IRC 2024 text. 16 in From a data sheet or an agency document · source
Screw spacing, wall at 24 in o.c.IRC Table R702.3.5, wall, framing 24 in o.c., without adhesive: screws not more than 12 in apart. Same figure in the IRC 2021 and IRC 2024 text. 12 in From a data sheet or an agency document · source
Screws in a pound, 1-1/4 inGrip-Rite coarse thread drywall screw table, #6 x 1-1/4 in, the length for 1/2 in board: 258 per pound. Retail listings print lower counts on the box (238 in a 1 lb box), and the count printed on the box governs. 258 screws/lb From a data sheet or an agency document
Screws in a pound, 1-5/8 inGrip-Rite coarse thread drywall screw table, #6 x 1-5/8 in, the length for 5/8 in board: 200 per pound. Retail listings print lower counts (189 per pound in a 5 lb box of 945). 200 screws/lb From a data sheet or an agency document
Tape per unit areaUSG Sheetrock Heavy joint tape data sheet: 370 ft per 1,000 ft² of board, which is 0.37 ft of tape per square foot. 0.37 ft/ft² From a data sheet or an agency document
One window openingA 3 x 4 ft window. Benjamin Moore takes 12 ft² as well, Sherwin-Williams 15. Inch Calculator's drywall page has no opening box at all. ≈ 12 ft² Trade convention

Code editions these pages read

  • IRC 2021 — R702.3.5

The clauses above are the ones the default edition states. Every page here lets you switch edition, and the clause numbers and limits change with it: IRC 2021 · IRC 2024

Estimates for planning. A licensed trade or engineer signs off the work, and your local authority has the last word on which edition applies.

Every Drywall calculator 9

Read at the source

Every constant on this site carries the tier it sits in and the document it came from. These are the documents, read in the text and not quoted from another calculator.

  • IRC 2021
  • IRC 2024